Recent Projects: RCA of Repeat Tube Failures

TETRA Engineering was recently contacted by a client in Asia concerning Superheater tube failures in a supercritical coal boiler and asked to conduct a Root Cause Analysis (RCA).  A senior Tetra engineer visited the plant to gather information on the history of the failures and relevant data to be used for the RCA.  The failures were occurring in one specific region of the boiler (in one instance not long after tube replacement), on hanger tubes concentrated at the right-hand side of the unit.  Observations made on the tube failures included

     
  • The gas temperature at the right-hand side of the boiler was often over 100°C higher than the left
  •  
  • Metallurgical analysis of failed samples revealed fish-mouth failures caused by short term overheating
  •  
  • Failures occured following increase from 60% load to full load
  •  

After the elimination of other possibilities, it was hypothesized that the tubes were overheating due to temporary loss of steam flow which, when combined with the higher gas temperatures at the RHS, led to a concentration of failures.  Following this, the operating conditions were modelled using Power Plant Simulator and Designer (PPSD) to evaluate the necessary conditions for these failures to occur.

It was shown that the under low loads, the steam may have been condensing at the bottom of the investigated hanger tubes due to low flue gas temperatures in this region (it entered the tubes only just above saturation).  This led to blockage of the tube and restricted steam flow.  When load increases, and gas temperatures increase, the tubes overheat – particularly at the RHS due to flue gas temperature skew.

For more information about this project contact Fraser Davidson at fraser.davidson@tetra-eng.com . For more information about our Failure Analysis Services contact James Malloy at jim.malloy@tetra-eng.com .

Technical Tidbits from the HRSG Inspection Planning Guide

Thermal overstress is generally associated with the high temperature sections of the HRSG (HP Superheater and Reheater).  Flow starvation in a tube relative to its neighbors results in the tube metal temperature approaching the gas temperature.  In that case, tube-to-tube differential temperatures may exceed 500°F (260°C).  The enormous thermal stress that results exceed material yield stress and cause permanent bowing…  

If you are interested in the full version of the HRSG Inspection Planning Guide (2nd edition) contact Ms Christine Vallon at christine.vallon@tetra-eng.com.  

 

Book a free consultation

Our goal is to protect the value of your investments and improve the performance of your assets.

Contact Us

More News

Stay up to date and refer to our large collection of technical white papers and articles

Power Plant Training Hosted by Tetra Engineering and TG Advisers in Florida
News

Power Plant Training Hosted by Tetra Engineering and TG Advisers in Florida

TETRA and TG advisers held a successful week of power plant training in Tampa, Florida...

Learn more
Predicting and Preventing HP Evaporator Tube Failures
News

Predicting and Preventing HP Evaporator Tube Failures

Two of the most common issues that power plant owners and operators face in the HP Evaporator section areUnder-deposit Corrosion (UDC) andCorrosion-Fatigue. In this short article we will cover UDC and what key actions should be taken to predict and prevent costly forced outages.

Learn more
HRSG Tube Failure Guide, 3rd Ed.
News

HRSG Tube Failure Guide, 3rd Ed.

The latest updated edition of Tetra Engineering's HRSG Tube Failure Diagnostic Guide will be published August 15, 2016. Thousands of combined cycle professionals are familiar with Tetra's HRSG Tube Failure Diagnostic Guide; first published during the 'bubble' in construction in the early 2000s.

Learn more

Contact Us

To discuss how we might assist you to improve your plant's performance or to maintain its value over time

Contact Us