HRSG Inspection Planning Guide (2nd Edition)

Inspection is part of routine maintenance for any Heat Recovery Steam Generator (HRSG). Visual inspections are performed at regular intervals in accordance with the requirements of regulatory bodies and insurers.Inspection is part of routine maintenance for any Heat Recovery Steam Generator (HRSG). Visual inspections are performed at regular intervals in accordance with the requirements of regulatory bodies and insurers.

HRSG Tube Failure Diagnostic Guide (3rd Edition)

Heat Recovery Steam Generator (HRSG) tubes provide the media for extraction of useful energy from the waste heat in gas turbine exhaust at combined cycle power plants (GT-CCs) or from heat generated by process streams at petrochemical facilities.

Technical White Papers

A selection of technical papers available for reference.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Inspection Technology for Heat Recovery Steam generators (HRSG)

Inspection Technology for Heat Recovery Steam generators (HRSG)

In addition to selecting inspection technology, the group responsible for inspection must have a clear underst...

learn more
Pressure Boundary Inspection Quick Guide

Pressure Boundary Inspection Quick Guide

Effective HRSG inspections focus on damage mechanisms that could affect each of the specific components; not all components are susceptible to all damage types.

learn more
HRSG Inspections - The Key to Reliability

HRSG Inspections - The Key to Reliability

Inspection is part of routine maintenance for any Heat Recovery Steam Generator (HRSG). Visual inspectio...

learn more
GT Upgrade Effects on HRSG Pressure Parts

GT Upgrade Effects on HRSG Pressure Parts

Tetra Engineering Group, Inc. (TETRA) has assisted the owners of natural gas-fired combined cycle plants with ...

learn more
HRSG Tube Failure Statistics

HRSG Tube Failure Statistics

Tetra Engineering Group, Inc. (TETRA) has assisted the owners of natural gas-fired combined cycle plants with ...

learn more

Contact Us

To discuss how we might assist you to improve your plant's performance or to maintain its value over time

Contact Us

Papers, Presentations and Articles

Selected papers, presentations and articles from major industry conferences and events.

Title
Author
Flow Accelerated Corrosion Failures in Nominally Low-Risk HRSG Tube Locations
Flow Accelerated Corrosion Failures in Nominally Low-Risk HRSG Tube LocationsFlow Accelerated Corrosion Failures in Nominally Low-Risk HRSG Tube Locations
Malloy J., Fabricius A., Taylor M., Rusaas J., Vestdam K.
Proceedings of the ASME 2022 Power Conference
Developing and Implementing Ch. VII O&M Programs at CCGT Plants: Case Studies
Developing and Implementing Ch. VII O&M Programs at CCGT Plants: Case StudiesDeveloping and Implementing Ch. VII O&M Programs at CCGT Plants: Case Studies
Jackson P., Rosario R., Johny A., Fabricius A., Wholey A.
ASME PVP 2021
The Change In Boiler and Steam Turbine Failure Modes With Minimum Load Operation - Supplemented With Modeling to Predict Susceptibility and Validation Through Plant Testing
The Change In Boiler and Steam Turbine Failure Modes With Minimum Load Operation - Supplemented With Modeling to Predict Susceptibility and Validation Through Plant TestingThe Change In Boiler and Steam Turbine Failure Modes With Minimum Load Operation - Supplemented With Modeling to Predict Susceptibility and Validation Through Plant Testing
Reid T., Malloy J., Scoffone M., Fabricius A., Reid, S.
ASME 2020 Virtual Power Conference
HRSG Fleet Integrity Management - Lessons Learned From The Field
HRSG Fleet Integrity Management - Lessons Learned From The FieldHRSG Fleet Integrity Management - Lessons Learned From The Field
Fabricius A., Jackson P., Taylor M.
ASME 2020 Virtual Power Conference
On The Use of Computational Fluid Dynamics (CFD) To Assess The Impact of Low-Load Operations on Heat Recovery Steam Generator (HRSG) Tube Module Integrity
On The Use of Computational Fluid Dynamics (CFD) To Assess The Impact of Low-Load Operations on Heat Recovery Steam Generator (HRSG) Tube Module IntegrityOn The Use of Computational Fluid Dynamics (CFD) To Assess The Impact of Low-Load Operations on Heat Recovery Steam Generator (HRSG) Tube Module Integrity
Fabricius A., Moelling D., Rusaas J.
ASME 2019 Power Conference, July 2019

Previous Projects

With over 30 years of experience in power and industrial steam generation services, Tetra Engineering has along history of projects.

HRSG Boiler Preservation Study, 2014
Middle East

HRSG Boiler Preservation Study, 2014

A CCGT power plant employed Tetra to perform a review of possible boiler preservation options within the context of the present and planned operating regime. The review relied on information supplied by the plant staff, Tetra field experience and latest industry trends and practices to identify the most promising strategy for preservation. The ideal solution for this client was Dry Layup that is systematically applied when it reaches the end of the standby period. This would require that resulting startup timing meets requirements imposed by the governing network operator.

Thermohydraulic Attemperator Study using PPS&D, 2014
Europe

Thermohydraulic Attemperator Study using PPS&D, 2014

The primary purpose of this study was to validate the effect of an interstage attemperator between two superheaters with respect to the primary superheater and primary reheater outlet steam temperatures. The CCGT in question had already had problems with creep failures of the P91 components, and needed to assure that exit temperatures did not exceed 570°C. Currently, the primary superheater outlet temperatures exceed 600°C at certain loads and the primary reheater temperatures exceed 590°C. Initial results were based on steady-state analysis, while final results included dynamic modeling of cold-, warm- and hot starts, as well as ramp up and ramp down. The study was performed using the software simulation tool PPS&D.

Stress Analysis Study of SH Section, 2014
South East Asia

Stress Analysis Study of SH Section, 2014

A CCGT Power Plant suffered repeated tube failures between 2003 and 2014 in the SH section of their boiler. Failures were exclusively located at the tube-header weld, at varying positions on the tube sheet. The client engaged Tetra Engineering to analyze the problem and simulate the existing stresses during various load conditions. The scope of work included a review of historical failures and metallurgical reports, operational data analysis, Finite Element Analysis (FEA) and Fatigue Analysis.

CFD Analysis of failed 180° Bend, 2013
Middle East

CFD Analysis of failed 180° Bend, 2013

A CFD study on one of the 4th quadrant pipe bends at a thermal power plant steam boiler was performed. The purpose of the analysis was to analyse the change in flow velocity due to an increase in the bend nominal size from 3” to 4”. The connecting pipe run was kept at 3” and standard expander/reducers are used to join the pipe with the bend. Input process parameters were taken from a PPSD model.