Ressources

Consultez notre gamme de ressources gratuites.

Nous contacter

Guides techniques

Tetra a publié une série de guides qui peuvent être commandés.

HRSG Inspection Planning Guide (2nd Edition)

Inspection is part of routine maintenance for any Heat Recovery Steam Generator (HRSG). Visual inspections are performed at regular intervals in accordance with the requirements of regulatory bodies and insurers.

HRSG Tube Failure Diagnostic Guide (3rd Edition)

Heat Recovery Steam Generator (HRSG) tubes provide the media for extraction of useful energy from the waste heat in gas turbine exhaust at combined cycle power plants (GT-CCs) or from heat generated by process streams at petrochemical facilities.

Article Techniques

Une sélection de documents techniques disponibles à titre de référence.

Merci ! Votre candidature a été reçue !
Oups ! Une erreur s'est produite lors de l'envoi du formulaire.
Grade 91 Steel

Grade 91 Steel

Background Early failures of components fabricated with Creep Strength Enhanced Ferritic (CSEF) Steels in con...

en savoir plus
Flow Accelerated Corrosion (FAC)

Flow Accelerated Corrosion (FAC)

Background Tube thinning caused by flow-accelerated corrosion (FAC) is one of the most frequent causes of fai...

en savoir plus
Reasons for Inspecting

Reasons for Inspecting

Inspection is part of routine maintenance for any Heat Recovery Steam Generator (HRSG). Visual inspectio...

en savoir plus
Piping Hangers & Supports

Piping Hangers & Supports

Piping supports and hangers require routine inspection. Interferences with equipment or structures can c...

en savoir plus
Sulphuric Acid Dewpoint Corrosion

Sulphuric Acid Dewpoint Corrosion

The key factor in determining rate of cold-end deposits in HRSGs firing natural gas is the sulphuric acid dew ...

en savoir plus
Surface Replica Testing

Surface Replica Testing

Preparation of surface replicas is considered a type of visual test. It has proven to be a valuable tool...

en savoir plus

Nous contacter

Pour discuter de la manière dont nous pouvons vous aider à améliorer les performances de votre usine ou à maintenir sa valeur au fil du temps

Nous contacter

Articles, présentations et articles

Sélection d'articles, de présentations et d'articles issus de conférences et d'événements majeurs de l'industrie.

Title
Author
Flow Accelerated Corrosion Failures in Nominally Low-Risk HRSG Tube Locations
Flow Accelerated Corrosion Failures in Nominally Low-Risk HRSG Tube LocationsFlow Accelerated Corrosion Failures in Nominally Low-Risk HRSG Tube Locations
Malloy J., Fabricius A., Taylor M., Rusaas J., Vestdam K.
Proceedings of the ASME 2022 Power Conference
Developing and Implementing Ch. VII O&M Programs at CCGT Plants: Case Studies
Developing and Implementing Ch. VII O&M Programs at CCGT Plants: Case StudiesDeveloping and Implementing Ch. VII O&M Programs at CCGT Plants: Case Studies
Jackson P., Rosario R., Johny A., Fabricius A., Wholey A.
ASME PVP 2021
The Change In Boiler and Steam Turbine Failure Modes With Minimum Load Operation - Supplemented With Modeling to Predict Susceptibility and Validation Through Plant Testing
The Change In Boiler and Steam Turbine Failure Modes With Minimum Load Operation - Supplemented With Modeling to Predict Susceptibility and Validation Through Plant TestingThe Change In Boiler and Steam Turbine Failure Modes With Minimum Load Operation - Supplemented With Modeling to Predict Susceptibility and Validation Through Plant Testing
Reid T., Malloy J., Scoffone M., Fabricius A., Reid, S.
ASME 2020 Virtual Power Conference
HRSG Fleet Integrity Management - Lessons Learned From The Field
HRSG Fleet Integrity Management - Lessons Learned From The FieldHRSG Fleet Integrity Management - Lessons Learned From The Field
Fabricius A., Jackson P., Taylor M.
ASME 2020 Virtual Power Conference
On The Use of Computational Fluid Dynamics (CFD) To Assess The Impact of Low-Load Operations on Heat Recovery Steam Generator (HRSG) Tube Module Integrity
On The Use of Computational Fluid Dynamics (CFD) To Assess The Impact of Low-Load Operations on Heat Recovery Steam Generator (HRSG) Tube Module IntegrityOn The Use of Computational Fluid Dynamics (CFD) To Assess The Impact of Low-Load Operations on Heat Recovery Steam Generator (HRSG) Tube Module Integrity
Fabricius A., Moelling D., Rusaas J.
ASME 2019 Power Conference, July 2019

Projets Récents

Avec plus de 30 ans d'expérience dans les services de production d'électricité et de vapeur industrielle, Tetra Engineering a une longue histoire de projets.

CFD Analysis of failed 180° Bend, 2013
Middle East

CFD Analysis of failed 180° Bend, 2013

A CFD study on one of the 4th quadrant pipe bends at a thermal power plant steam boiler was performed. The purpose of the analysis was to analyse the change in flow velocity due to an increase in the bend nominal size from 3” to 4”. The connecting pipe run was kept at 3” and standard expander/reducers are used to join the pipe with the bend. Input process parameters were taken from a PPSD model.

LP Economiser Header Failure Analysis, 2010
Middle East

LP Economiser Header Failure Analysis, 2010

The LP economiser lower header on a HRSG ruptured shortly after a diverter damper incident. Tetra was approached by the client to investigate the possible root causes for the rupture. The unit went into single element control at the time of the incident and the LCV cycled through fully open / fully closed positions to maintain the drum level after “shrink”. When the damper re-opened the LCV remained closed as the drum level increased (swell). The economizer temperature increased and there was an associated increase in pressure. The safety valve failed to operate as it was accidentally gagged, causing serious over pressurisation and a burst header.

Nous contacter

Pour discuter de la manière dont nous pouvons vous aider à améliorer les performances de votre usine ou à maintenir sa valeur au fil du temps

Nous contacter